联系我们
意见反馈

关注公众号

获得最新科研资讯

简历详情
杨真
广西桂林 | 广西师范大学-电子与信息工程学院 | 院长助理
  邮箱   zy2020@gxnu.edu.cn  电话   159****8588
TA的实验室:   Magnetic MEMS Group
论文

Design, Simulation, and Fabrication of a New Three-Axis Inertial Switch with a Triangular Movable Electrode Structure

A new three-axis inertial switch is proposed. The triangle-structured movable electrode is designed to improve the inertial switch’s dynamic response performance, especially the movable electrode’s dynamic stability performance. The static mechanical analysis indicated that the displacement of the movable electrode to the fixed electrode in the sensitive direction is the minimum when the acceleration is applied to this designed inertial switch. The dynamic simulation analysis showed that the threshold of the designed inertial is about 235 g. The threshold in the non-sensitive direction is about 240 g, 270 g, 300 g, and 350 g when the directions of applied acceleration deviate 15°, 30°, 45°, and 60° from the sensitive direction, respectively. These results indicated that the designed inertial could resist the impact in non-sensitive directions and improve the stability in sensitive directions. The prototype of the inertial switch was fabricated and tested successfully. The testing results indicate that the threshold of the fabricated inertial switch is about 219 g. The test results verify the dynamic stability performance of the designed inertial switch.

期刊: Micromachines  2022
作者: Zhen Yang,Huiying Wang,Rui Wang,Wenguo Chen
DOI:10.3390/mi14010094

Ligand‐Modulated Excess PbI 2 Nanosheets for Highly Efficient and Stable Perovskite Solar Cells

期刊: Advanced Materials  2020
作者: Jingshan Luo,Anders Hagfeldt,Xiaodan Zhang,Yongsong Luo,Ying Zhao,Gang Chen,Ke Meng,Zhuang Zhang,Chenyi Yi,Liguo Tan,Yi Ding,Yuzeng Xu,Zhen Yang,Zaiwei Wang,Huanhuan Wang
DOI:10.1002/adma.202000865

Magnetic Properties and Giant Magnetic Impedance of Amorphous CoFeNISiB Ribbons in the Form of Micromeanders

期刊: Inorganic Materials: Applied Research  2020
作者: S. V. Shcherbinin,S. O. Volchkov,E. V. Golubeva,Zhen Yang
DOI:10.1134/s2075113320040097

Magnetoimpedance Effect in the Ribbon-Based Patterned Soft Ferromagnetic Meander-Shaped Elements for Sensor Application

Amorphous and nanocrystalline soft magnetic materials have attracted much attention in the area of sensor applications. In this work, the magnetoimpedance (MI) effect of patterned soft ferromagnetic meander-shaped sensor elements has been investigated. They were fabricated starting from the cobalt-based amorphous ribbon using the lithography technique and chemical etching. Three-turn (S1: spacing s = 50 μm, width w = 300 μm, length l = 5 mm; S2: spacing s = 50 μm, width w = 400 μm, length l = 5 mm) and six-turn (S3: s = 40 μm, w = 250 μm, length l = 5 mm; S4: s = 40 μm, w = 250 μm and l = 8 mm) meanders were designed. The ‘n’ shaped meander part was denominated as “one turn”. The S4 meander possesses a maximum MI ratio calculated for the total impedance ΔZ/Z ≈ 250% with a sensitivity of about 36%/Oe (for the frequency of about 45 MHz), and an MI ratio calculated for the real part of the total impedance ΔR/R ≈ 250% with the sensitivity of about 32%/Oe (for the frequency of 50 MHz). Chemical etching and the length of the samples had a strong impact on the surface magnetic properties and the magnetoimpedance. A comparative analysis of the surface magnetic properties obtained by the magneto-optical Kerr technique and MI data shows that the designed ferromagnetic meander-shaped sensor elements can be recommended for high frequency sensor applications focused on the large drop analysis. Here we understand a single large drop as the water-based sample to analyze, placed onto the surface of the MI sensor element either by microsyringe (volue range 0.5–500 μL) or automatic dispenser (volume range 0.1–50 mL).

期刊: Sensors  2019
作者: Galina V. Kurlyandskaya,Sergei V. Shcherbinin,Pengfei Guo,Stanislav O. Volchkov,Elizaveta V. Golubeva,Anna A. Chlenova,Zhen Yang
DOI:10.3390/s19112468

ZnO-templated N-doped holey graphene for efficient lithium ion storage performance

期刊: Materials Chemistry and Physics  2018
作者: Yongsong Luo,Yang Lu,Xu Wu,Wenchao Yang,Zhen Yang,Xinwei Dong
DOI:10.1016/j.matchemphys.2017.11.054

A sensitive and innovative detection method for rapid C-reactive proteins analysis based on a micro-fluxgate sensor system

期刊: PLOS ONE  2018
作者: Yong Zhou,Chong Lei,Zhu Feng,Shaotao Zhi,Zhen Yang,Lei Guo
DOI:10.1371/journal.pone.0194631

A Multi-Region Magnetoimpedance-Based Bio-Analytical System for Ultrasensitive Simultaneous Determination of Cardiac Biomarkers Myoglobin and C-Reactive Protein

期刊: Sensors  2018
作者: Yongsong Luo,Chong Lei,Yuanyuan Ding,Pengfei Guo,Huanhuan Wang,Zhen Yang
DOI:10.3390/s18061765

Sensitive detection of cardiac troponin T based on superparamagnetic bead-labels using a flexible micro-fluxgate sensor

In this study, we describe an innovative micro-fluxgate immunosensor based on superparamagnetic Dynabeads for the detection of cardiac troponin T (cTnT), an important biomarker for cardiovascular diseases.

期刊: RSC Advances  2017
作者: Yong Zhou,Chong Lei,Zhu Feng,Shaotao Zhi,Zhen Yang,Lei Guo
DOI:10.1039/c7ra10355g

Densely-stacked N-doped porous carbon monolith derived from sucrose for high-volumetric energy storages

期刊: Electrochimica Acta  2017
作者: Yafei Zhang,Nantao Hu,Ming Li,Taiqiang Chen,Yongsong Luo,Xu Wu,Zhen Yang,Xinwei Dong
DOI:10.1016/j.electacta.2017.08.108

Giant magnetoimpedance based immunoassay for cardiac biomarker myoglobin

A GMI sensor integrated with a microcavity was fabricated by micro-electro-mechanical-system (MEMS) technology.

期刊: Analytical Methods  2017
作者: Yongsong Luo,Chong Lei,Hailong Yan,Xinwei Dong,Huanhuan Wang,Zhen Yang
DOI:10.1039/c7ay00981j

A Study on Giant Magnetoimpedance Effect in VITROVAC 6025Z Micro-patterned Ribbons

期刊: MATEC Web of Conferences  2016
作者: Chong Lei,Tianqi Fan,Zhen Yang
DOI:10.1051/matecconf/20178801003

Ultrasensitive detection and quantification of E. coli O157:H7 using a giant magnetoimpedance sensor in an open-surface microfluidic cavity covered with an antibody-modified gold surface

期刊: Microchimica Acta  2016
作者: Yong Zhou,Xue-Cheng Sun,Chong Lei,Yan Liu,Zhen Yang
DOI:10.1007/s00604-016-1818-3

Enhanced GMI effect in tortuous-shaped Co-based amorphous ribbons coated with graphene

期刊: Journal of Materials Science: Materials in Electronics  2015
作者: Yan Liu,Yong Zhou,Xue-Cheng Sun,Chong Lei,Zhen Yang
DOI:10.1007/s10854-015-4183-9

A Dynabeads-labeled immunoassay based on a fluxgate biosensor for the detection of biomarkers

Magnetic bead-based biosensors are becoming a hot spot in biomedical fields. A Dynabeads-labeled immunoassay has been developed using a micro fluxgate biosensor for the detection of alpha fetoprotein (AFP) and carcinoembryonic antigen (CEA).

期刊: Analytical Methods  2015
作者: Yan Liu,Yong Zhou,Chong Lei,Xue-Cheng Sun,Jian Lei,Zhen Yang
DOI:10.1039/c4ay02727b

A GMI biochip platform based on Co-based amorphous ribbon for the detection of magnetic Dynabeads

A giant magnetoimpedance (GMI) biochip platform for the low concentration detection of streptavidin-coupled magnetic Dynabeads of different sizes was successfully fabricated.

期刊: Analytical Methods  2015
作者: Xue-Cheng Sun,Yan Liu,Yong Zhou,Chong Lei,Zhen Yang
DOI:10.1039/c5ay01498k

A flexible giant magnetoimpedance-based biosensor for the determination of the biomarker C-reactive protein

期刊: Microchimica Acta  2015
作者: Yong Zhou,Xue-Cheng Sun,Chong Lei,Yan Liu,Zhen Yang
DOI:10.1007/s00604-015-1587-4

A giant magnetoimpedance-based biosensor for sensitive detection of Escherichia coli O157:H7

期刊: Biomedical Microdevices  2015
作者: Jian Lei,Yong Zhou,Yan Liu,Chong Lei,Tao Wang,Xue-Cheng Sun,Zhen Yang
DOI:10.1007/s10544-014-9925-6

An innovative detecting way of Escherichia coli O157H:H7 by a micro-fluxgate-based bio-sensing system

期刊: Sensors and Actuators B: Chemical  2015
作者: Yong Zhou,Lei Guo,Yan Liu,Chong Lei,Zhen Yang,Xue-Cheng Sun
DOI:10.1016/j.snb.2015.07.040

Improved Performance of Integrated Solenoid Fluxgate Sensor Chip Using a Bilayer Co-Based Ribbon Core

期刊: IEEE Sensors Journal  2015
作者: Yong Zhou,Zhen Yang,Tao Wang,Xue-Cheng Sun,Yan Liu,Chong Lei
DOI:10.1109/jsen.2015.2432457

Meander-shaped magnetoimpedance sensor for measuring inhomogeneous magnetic fringe fields of NiFe films

期刊: Applied Physics Letters  2014
作者: Yong Zhou,Yan Liu,Xuecheng Sun,Zhen Yang,Chong Lei,Tao Wang
DOI:10.1063/1.4900786

Effect of magnetic field annealing and size on the giant magnetoimpedance in micro-patterned Co-based ribbon with a meander structure

期刊: Applied Physics A  2014
作者: Tao Wang,Yong Zhou,Chong Lei,Jian Lei,Zhen Yang
DOI:10.1007/s00339-014-8343-1

Quantitative determination of magnetic beads using a magnetoimpedance-based lab-on-a-chip platform

期刊: Journal of Applied Physics  2014
作者: Yong Zhou,Jian Lei,Chong Lei,Zhen Yang,Tao Wang
DOI:10.1063/1.4882095

An integrated giant magnetoimpedance biosensor for detection of biomarker

期刊: Biosensors and Bioelectronics  2014
作者: Yong Zhou,Jian Lei,Chong Lei,Zhen Yang,Tao Wang
DOI:10.1016/j.bios.2014.03.008

Study on the giant magnetoimpedance effect in micro-patterned Co-based amorphous ribbons with single strip structure and tortuous shape

期刊: Microsystem Technologies  2014
作者: Xue-Cheng Sun,Yong Zhou,Chong Lei,Zhen Yang
DOI:10.1007/s00542-014-2342-1

A giant magnetoimpedance sensor for sensitive detection of streptavidin-coupled Dynabeads

期刊: physica status solidi (a)  2014
作者: Yong Zhou,Jian Lei,Chong Lei,Zhen Yang,Tao Wang
DOI:10.1002/pssa.201330309

Detection of Dynabeads in small bias magnetic field by a micro fluxgate-based sensing system

期刊: Journal of Applied Physics  2014
作者: Yong Zhou,Zhen Yang,Tao Wang,Jian Lei,Cui Liu,Xue-Cheng Sun,Chong Lei
DOI:10.1063/1.4898360

Effect of annealing orientation on the giant magnetoimpedance in micro-patterned Co-based ribbon

期刊: 2014 12th IEEE International Conference on Solid-State and Integrated Circuit Technology (ICSICT)  2014
作者: Xue-Cheng Sun,Chong Lei,Yong Zhou,Zhen Yang
DOI:10.1109/icsict.2014.7021510

Development of an ingenious method for determination of Dynabeads protein A based on a giant magnetoimpedance sensor

期刊: Sensors and Actuators B: Chemical  2013
作者: Zhen Yang,Jian Lei,Chong Lei,Yong Zhou,Tao Wang
DOI:10.1016/j.snb.2013.06.052

Detection of targeted carcinoembryonic antigens using a micro-fluxgate-based biosensor

期刊: Applied Physics Letters  2013
作者: Yong Zhou,Zhen Yang,Tao Wang,Chong Lei,Jian Lei
DOI:10.1063/1.4831687

A MEMS-fluxgate-based sensing system for the detection of Dynabeads

期刊: Journal of Micromechanics and Microengineering  2013
作者: Yong Zhou,Zhen Yang,Tao Wang,Chong Lei,Jian Lei
DOI:10.1088/0960-1317/23/9/095005

Ultrasensitive detection of Dynabeads protein A using the giant magnetoimpedance effect

期刊: Microchimica Acta  2013
作者: Zhen Yang,Jian Lei,Chong Lei,Yong Zhou,Tao Wang
DOI:10.1007/s00604-013-1016-5

Investigation of targeted biomolecules in a micro-fluxgate-based bio-sensing system

期刊: Biomedical Microdevices  2013
作者: Yong Zhou,Zhen Yang,Tao Wang,Chong Lei,Jian Lei
DOI:10.1007/s10544-013-9827-z

Preparation of meander thin-film microsensor and investigation the influence of structural parameters on the giant magnetoimpedance effect

期刊: Applied Physics A  2012
作者: Yong Zhou,Zhen Yang,Jian Lei,Chong Lei,Tao Wang
DOI:10.1007/s00339-012-7034-z

A low power micro fluxgate sensor with improved magnetic core

期刊: Microsystem Technologies  2012
作者: Yong Zhou,Tao Wang,Zhen Yang,Jian Lei,Chong Lei
DOI:10.1007/s00542-012-1669-8

Improved micro fluxgate sensor with double-layer Fe-based amorphous core

期刊: Microsystem Technologies  2012
作者: Yong Zhou,Zhen Yang,Jian Lei,Chong Lei
DOI:10.1007/s00542-012-1523-z

主页访问量:146